Viscometer SV-10 / SV-100
High
Measurement Accuracy Tuning-fork Vibration Method
provides for excellent repeatability
of 1% of reading for viscosity
measurement by our Sine-wave Vibro
Viscometers SV-10 / SV-100.
Low Viscosity
Measurement And Wide Measurement
Range Low viscosity of 0.3 mPa·s (
cP ) to high viscosity of 10,000
mPa·s ( cP ) sample fluid can be
measured by the SV-10 and 1000mPa s
(cP) to 100,000mPa s (cP) by the
SV-100, without changing the sensor
plates.
Real-Time
Measurement The sensor plate is thin and
small, in area and in mass, making
it is less influenced by the
temperature change of the sample
fluid and as a result the viscosity
measurement tracks the change of
viscosity of the sample fluid.
SV Series
Model
Range
SV-10
0.3 mPa·s (cP)
to
10,000 mPa·s (cP)
SV-100
1,000mPa s (cP)
to
100,000mPa s (cP)
Temperature Measurement It is very important to measure the temperature of
the fluid correctly because the viscosity is very much
dependent upon this temperature. The SV series can detect an
accurate temperature immediately because the fluid and the
detection unit (sensor plates), with small surface
area/thermal capacity, reach thermal equilibrium in only a
few seconds.
Continuous measurement The SV series, Tuning-fork Vibration Method does not
cause damage to the sample fluid and allows measurement of
cloud point of samples such as surface active agents and of
surface/interface changes such as wet ability because of its
excellent feature of a wide measurement range without the
need to replace the sensor plates.
Viscosity Calibration With Viscosity Standard, viscosity calibration can be
easily done. 1 point calibration or 2 points calibration is
selectable in the calibration mode.
Non-Newtonian Sample Viscosity Measurement Thin sensor plates allow little deformation of sample
texture and thus enable measurement of stable viscosity
values.
Foaming Sample Measurement The low drive frequency of 30Hz allows measurement of
foaming samples without breaking minute foams and with less
scattering of larger foams.
Flowing Sample Measurement Even the viscosity of flowing samples can be
measured, including liquid in turbulent flow. This provides
field management with identical data to that obtained in the
laboratories.
Separated type model The SV series comprise a separate Display Unit and
Main Unit offering excellent placement flexibility.
Vacuum Fluorescent Display Reading errors are avoided with the easy-to-read,
large, clear display: 13mm height for viscosity measurement
and 11mm height for temperature measurement.
Small Sample Size The standard sample cup requires just over 35 ml thus
reducing waste.
Easy Cleaning Due to the simple structure, the SV series sensor
plates, temperature sensor and the protector made of
stainless steel (SUS 304) can all be easily and quickly
cleaned.
Sol and Gel Measurement Sol and Gel samples can be measured during the change
of material state.
Standard RS-232C Interface RS-232C interface and a data connection cable
(DB25-DB9) are supplied as standard for your PC or printer
connectivity.